2019-06-05 18:35:00 | ALL | 999 | ALL | deployed by the R/V Connecticut |
2019-06-10 12:00:00 | ALL | 0 | waves_3 | Microstrain wave data locked up several times during deployment. |
2019-06-14 05:00:00 | ALL | 0 | goes | Goes transmissions becoming very intermittent - signal strength dropped from near 40 to 30 or below. |
2019-10-03 09:00:00 | ALL | 0 | waves_3 | Microstrain failed (invalid clock data). When restarted on 2019-11-07, clock had not advanced. Timestamps are wrong use data with caution. |
2019-10-03 18:00:00 | visibility | 0 | met | Vis sensor started reading continuously high at about 1800, flatline ever since |
2019-10-10 20:00:00 | 20 | sbe37 | instrument stopped reporting. unable to communicate with it. clock time shifted just before going off air | |
2019-11-01 09:00:00 | ALL | 0 | ALL | Buoy dragged anchor 50m to ENE during coastal storm. |
2020-01-24 01:20:00 | wind_direction | -4 | met | Wind direction from RMYoung backup wind sensor is invalid (compass failure assciated with blown met fuse). |
2020-02-04 20:00:00 | ALL | 1 | sbe37 | Last data received from 1m SBE - all data sent back are zero. |
2020-06-02 12:35:00 | ALL | 999 | ALL | instrument swap by RV Osprey |