Mooring Events: A0137

2017-06-28 00:50:00 ALL 999 ALL deployed by the Warren
2017-06-28 01:00:00 dissolved_oxygen 50 sbe16 Dissolved oxgyen sensor at 50m failed (voltage reading of zero volts).
2017-06-28 01:00:00 wind_speed,wind_gust -4 met Backup wind speeds too high at minutes 50 and 00. During the rest of the hour, the backup wind speeds compare well to those measured by the primary wind sensor.
2017-06-28 01:00:00 visibility -3 met Visibility readings flagged as invalid (intermittent periods when values seem to be tracking buoy battery).
2017-06-28 01:00:00 percent_oxygen_saturation 2 aanderaa Optode reading too low/erratic.
2017-07-04 17:00:00 wind_speed,wind_gust -4 met New program loaded into control box remotely; valid backup wind data being received after GPS sampling time was shifted.
2017-07-07 17:00:00 ALL 50 sbe16 SBE16+ inadvertently taken out of sampling mode
2017-07-10 22:00:00 ALL 50 sbe16 SBE16+ sampling resumed after instrument talk-through to restart sampling.
2017-07-17 16:45:00 ALL 20 suna Last data received from 20m SUNA nitrate sensor. Talkthrough to instrument indicates instrument is in adaptive mode sampling due to reduction in light (possible biological fouling).
2017-07-23 08:00:00 ALL 20 suna Data transmissions from 20m SUNA nitrate sensor have resumed
2017-07-26 23:00:00 gps_lat,gps_lon -3 diagnostics Last valid data received from primary GPS; backup Goes GPS still working properly.
2017-08-10 18:00:00 ALL 20 suna Data transmissions from 20m SUNA nitrate sensor have stopped once again.
2017-12-07 16:42:00 ALL 999 ALL recovered by the R/V Connecticut


Download | Sensor Information | Software | NERACOOS Gulf of Maine Moorings | NERACOOS Home